What a synthesis laboratory needs before it can quote
Custom work is quoted against a specification. If the specification is a name in an email, the quotation is a guess with a number attached.
On this page
The structure, with stereochemistry drawn
A two-dimensional skeleton leaves the stereocentres to the reader. Draw them, or state the configuration in words. The same applies to double bond geometry and to ring conformations where a single isomer is wanted. A synthesis aimed at the wrong diastereomer costs a campaign and produces material nobody can use.
Quantity, form and purity target
State the mass you need, not the mass you hope to need. Scale changes the route: a milligram-scale purification and a hundred-gram campaign do not share a method. Say whether a solid is required or a solution will do, and give the purity target as a number with the method that will measure it. A target of "as pure as possible" cannot be tested against.
What the material has to support
Identification only, or quantitative use with an assigned content. Quantitative use brings an extra set of requirements: a value with an uncertainty, a documented assignment route and a stability statement. Say which, because it changes the analytical work that follows the synthesis.
If the compound is intended for a regulatory filing, say so at the enquiry stage. The documentation package is designed differently when it will be read by an assessor.
Route preferences and constraints
Some customers have a route in mind, or a route they must avoid because of a patent position or an internal safety rule. Some have an intermediate available that would shorten the work. Passing that on saves a step and sometimes the whole campaign.
Confidentiality arrangements belong here too, not after the structure has been sent.
The analytical package that comes with the material
Ask what will be delivered alongside the compound. A certificate stating identity and content is the minimum; the data behind those statements is what makes them usable. Proton and carbon NMR, a high-resolution mass measurement, a chromatogram at a stated wavelength and a quantitative result with its method form the usual set.
Say in advance if you need the raw data rather than the summary. Recovering spectra after a project closes is harder than asking for them at the start, and a filing often needs the original files rather than a table of numbers.
Agree the acceptance criteria before the work begins. A purity figure delivered without an agreed method can be argued about indefinitely, and the argument is more expensive than the analysis.
What we can supply
Custom items quoted against a structure, with the delivered material carrying a lot-specific certificate stating identity evidence and assigned content. Where the compound corresponds to a pharmacopoeial definition, the item is described against that definition so the correspondence is explicit rather than assumed. Structures, formulae and exact masses are published for catalogue items, and custom items are described the same way.
Frequently asked
How detailed does the structure need to be?
Can a custom item be supplied as a solution?
Does a custom standard come with an assigned content?
Sources and further reading
Every document below is published by the body that owns it; none of them is a summary written by us. Accessed 2026-11-24.
- ICH — Quality guidelines (Q-series) — the impurity and validation frame a custom standard has to serve
- ICH — M7(R2) assessment and control of DNA reactive impurities — why some custom items need a toxicological frame as well
- USP — Reference Standards — how official reference standards are established and documented
Send us a CAS number
Availability, documentation and lead time — answered by the people who handle the batch, not a ticket queue.