Skip to content
Technical & commercial enquiries: sales@rssechem.com Certificate of analysis issued per lot · Worldwide shipping
Register Request a quote & Contact us

Reporting, identification and qualification thresholds by dose

Impurities & regulation Published By RSSE Technical Team · Reviewed by RSSE Quality Unit

Three thresholds, three different obligations, and a set of bands that does not line up between the drug substance table and the drug product table. This works through the arithmetic at real dose levels, shows where the milligram cap replaces the percentage, and sets out what each limit forces a laboratory to buy or build.

On this page

Three thresholds, three different obligations

A reporting threshold is the level above which a result has to appear in the application, numerically and per batch. An identification threshold is the level above which the structure has to be established. A qualification threshold is the level above which the safety of that level has to be supported by data. They are three separate obligations that happen to be printed next to each other, and the most common error in a batch review is to treat the first number in the row as the limit for all three.

All of these thresholds scale with dose because the concern is intake, not concentration. Ten micrograms a day from a 10 mg tablet and ten micrograms a day from a 1 g tablet are the same exposure in very different percentages, which is why a table keyed only to percentage would be wrong at both ends.

Drug substance: one table with two limbs

The substance thresholds sit in a single table with a step at 2 g per day.

Maximum daily dose ReportingIdentificationQualification
2 g or less0.05%0.10% or 1.0 mg per day, whichever is lower 0.15% or 1.0 mg per day, whichever is lower
More than 2 g0.03%0.05%0.05%

The phrase whichever is lower turns each cell into two rules, and only one of them can bind at any given dose. Both convert into the same currency: at a percentage p and a dose D in grams, the intake in milligrams is p multiplied by D and by ten. So a 1.0 mg cap corresponds to a percentage of 0.1 divided by D.

Maximum daily dose IdentificationQualificationWhich limb binds
0.25 g0.10%0.15%Percentage, both limits
0.667 g0.10%0.15%Percentage, at the qualification crossover
1.0 g0.10%0.10%Cap reaches the percentage for identification
1.5 g0.067%0.067%1.0 mg cap, both limits
2.0 g0.05%0.05%1.0 mg cap, both limits
3.0 g0.05%0.05%Upper band of the table

Two crossovers fall out of that arithmetic. The qualification cap takes over above about 667 mg per day, because 1.0 mg is 0.15 per cent of 667 mg. The identification cap takes over above 1.0 g, because 1.0 mg is 0.10 per cent of 1.0 g. Between 667 mg and 1.0 g the qualification limit is a mass while the identification limit is still a percentage, so the two numbers on the same row are in different units and cannot be compared until one is converted.

The step at 2 g is not smooth. Reporting falls from 0.05 to 0.03 per cent, which is the point where the analytical requirement moves: the quantitation limit of the method must be no more than the reporting threshold, so a 3 g per day product needs a method that quantifies 0.03 per cent of a concentrated sample solution. That is a method development task, not a reporting formality.

Drug product: three tables banded three different ways

The degradation product thresholds are split across three tables, and the bands do not share boundaries. Reporting changes at 1 g. Identification changes at 1 mg, 10 mg and 2 g. Qualification changes at 10 mg, 100 mg and 2 g. A single dose therefore sits in three different bands at once.

Maximum daily dose ReportingIdentificationQualification
Up to 1 mg0.1%1.0% or 5 µg1.0% or 50 µg
1 to 10 mg0.1%0.5% or 20 µg1.0% or 50 µg
10 to 100 mg0.1%0.2% or 2 mg0.5% or 200 µg
100 mg to 1 g0.1%0.2% or 2 mg0.2% or 3 mg
1 to 2 g0.05%0.2% or 2 mg0.2% or 3 mg
More than 2 g0.05%0.10%0.15%

Here the qualification limit is usually a mass, and it is usually the tighter of the two. Work it out at three doses that a laboratory actually meets.

Maximum daily dose IdentificationQualificationWhat the gap means
5 mg0.4% (20 µg)1.0% (50 µg) Structure needed long before safety data
50 mg0.2% (100 µg)0.4% (200 µg) A band where identification alone applies
1.5 g0.133% (2 mg)0.2% (3 mg) Identification binds below qualification

At 5 mg per day the identification threshold is 0.4 per cent, because 20 micrograms is the binding limb, and the qualification threshold is a full 1.0 per cent. Between those two figures a peak must be identified and does not need safety data. At 50 mg, the figures are 0.2 and 0.4 per cent, so an impurity at 0.35 per cent is identified and left alone. At 1.5 g the order inverts: identification is 0.133 per cent while qualification is 0.2 per cent, so any peak that has to be identified is already below the qualification limit and that limit never decides anything. A reviewer who assumes qualification is always the stricter number will misread the last row in particular.

The comparison rule decides the borderline case

Thresholds are exceeded on a strict greater-than basis, and the comparison is made after rounding. When the threshold is a percentage, the reported result is rounded to the same number of decimal places as the threshold and compared directly. When the threshold is a mass, the result is converted to a total daily intake, rounded to the same number of decimal places, and compared.

The published example is worth memorising. At a 0.8 g dose the qualification threshold is 1.0 mg per day, which is 0.125 per cent. A result of 0.12 per cent converts to 0.96 mg, rounds to 1.0 mg, and does not exceed the threshold. The same result at a 0.5 g dose, where the qualification threshold is 0.15 per cent, is above it. Nothing about the chromatogram changed; only the dose did.

Reporting conventions compound this. Below 1.0 per cent results are reported to two decimal places and at or above 1.0 per cent to one, so an early result of 0.0963 per cent becomes 0.10 per cent on the form. If the laboratory has not fixed that convention before the batch record is written, the same numerical result can be argued either side of the threshold.

What each threshold forces you to buy or build

ThresholdEvidence needed Artefact that produces it
ReportingA validated method whose quantitation limit is at or below the reporting threshold, plus a numerical result per batchSpiked sample at the reporting level; the impurity standard is optional if response is corrected
IdentificationStructure assigned, with the assignment documented Characterised impurity standard for retention and confirmation, or isolation plus spectroscopy
QualificationSafety of the observed level, by study, literature or metabolic argumentSpiked samples at and above the level, which in turn needs a quantified impurity standard to spike accurately

The reporting row carries an obligation that is easy to miss and expensive to fix late. If the quantitation limit sits above the reporting threshold, the method cannot support the threshold at all, and no amount of extra batch data repairs it. The lower range limit is treated as its own validation subject for exactly this reason.

The identification row is where a relative retention time is often offered instead of a standard. That substitution works for tracking a peak between runs and does not work for establishing identity, and the difference becomes visible the moment a second method gives the peak a different relative retention. For the qualification row, the same standard is used differently: not to locate a peak but to prepare samples with a known added amount, which is what turns a safety argument into a demonstration that the method measures what the argument is about.

Where a standard for the impurity does not exist, the practical sequence is isolation from an enriched mother liquor, structure elucidation, then assignment of a response factor. The impurity profile comparison work that follows depends on that response factor, and an assumed value of 1.0 is only defensible when the chromophore is close to the parent.

Where the tables stop

Three exclusions decide more cases than the table itself. DNA reactive impurities do not follow a percentage at all; they are controlled against a threshold of toxicological concern of 1.5 micrograms per day, which is orders of magnitude below the percentage thresholds and is the subject of the M7 route from classification to control strategy. Enantiomeric impurities are outside the substance and product guidelines, and are handled through chiral methods and their own acceptance criteria. Residual solvents and elemental impurities have their own limits, keyed to permitted daily exposure rather than to percentage of the drug.

Two further points keep the table honest. A degradation product seen only at the recommended storage conditions drives identification, while one produced only under forced degradation belongs to the specificity argument for the method. And the percentage is a percentage of the substance, not of the peak area, so the impurity standard used for the calculation has to carry an assigned value with a stated uncertainty, not merely a certificate that says the material is the right molecule.

A review checklist

  • Confirm the dose used is the maximum recommended daily dose, not the strength on the label.
  • Write down which limb binds for each of the three thresholds at that dose, in per cent and in mass.
  • Check that the substance table was used for process impurities and the product table for degradation products.
  • Confirm the quantitation limit is at or below the reporting threshold, at the sample concentration actually injected.
  • List every peak above the identification threshold and state how each structure was assigned.
  • For every peak above the qualification threshold, state the basis: study, literature or metabolic argument.
  • Record the rounding convention used, and re-check any result within one decimal place of a threshold.
  • Confirm that no DNA reactive structure, enantiomer, solvent or elemental impurity was routed through these tables.

Frequently asked

Is the identification threshold the same as the limit in my specification?
No. The threshold is the level above which an action is required. The acceptance criterion is set separately, usually tighter than the threshold and justified by batch data, capability and stability. A specification written at exactly 0.10 per cent is a choice, not a requirement.
A result comes out at exactly 0.10 per cent. Is the threshold exceeded?
Not on the guideline wording, which uses greater than rather than greater than or equal to. The comparison is made on the result rounded to the same number of decimal places as the threshold, so 0.0963 per cent is reported as 0.10 per cent and does not exceed a 0.10 per cent threshold. That is also why the reporting rule matters: without a stated rounding convention, borderline results become arguments.
Does an impurity seen only in a forced degradation sample have to be identified?
The obligation is attached to batches made by the proposed commercial process and to degradation products observed in stability studies at the recommended storage conditions. Stress conditions exist to show that the method detects what the product can form; they do not by themselves put every peak on the identification list.
An impurity is present in both the substance and the product. Which table applies?
Process-related impurities in the substance are not monitored in the product unless they are also degradation products. Once a substance impurity also forms or grows in the product, it is a degradation product and the drug product table governs it, which is usually the stricter of the two at low dose.
Do these thresholds apply to a peptide or an oligonucleotide?
No. The scope of the substance guideline excludes biological and biotechnological products, peptides, oligonucleotides, radiopharmaceuticals, fermentation products and herbal materials. Those materials are handled under product-specific expectations, and applying a 0.10 per cent table to them is a common and expensive mistake.
What do I need to buy to satisfy an identification threshold?
A characterised standard of that impurity, enough to assign the peak and to confirm the structure, or an isolation and structure elucidation route if no standard exists. A relative retention time alone documents where a peak sits; it does not establish what the peak is, and a reviewer will treat the two as different claims.

Sources and further reading

Every document below is published by the body that owns it; none of them is a summary written by us. Accessed 2026-11-09.

  • ICH - Q3A(R2) Impurities in New Drug Substances — the reporting, identification and qualification thresholds for a new drug substance split at a maximum daily dose of 2 g, the requirement that the quantitation limit be not more than the reporting threshold, and the worked examples showing how a threshold expressed as a total daily intake is compared with a result
  • ICH - Q3B(R2) Impurities in New Drug Products — the three separate threshold tables for degradation products, banded at 1 g for reporting, at 1 mg, 10 mg and 2 g for identification and at 10 mg, 100 mg and 2 g for qualification, with the 50 mg maximum daily dose example
  • ICH - M7(R2) Assessment and control of DNA reactive impurities — the statement that Q3A(R2) and Q3B(R2) cover the majority of impurities but give limited guidance for DNA reactive ones, and the 1.5 microgram per day threshold of toxicological concern used instead of a percentage
  • ICH - Q2(R2) Validation of analytical procedures — the treatment of the lower range limit as a separate validation subject, where the quantitation limit sits close to the limit of the procedure and needs its own evidence
  • ISO - ISO 17034 General requirements for the competence of reference material producers — the characterisation, homogeneity and stability requirements behind a reference material that is used to assign a level rather than to confirm a retention time
  • EDQM - Reference Standards — the status of a pharmacopoeial reference standard as a material established for use with named monographs, which is what makes a compendial identification test reproducible between laboratories

Send us a CAS number

Availability, documentation and lead time — answered by the people who handle the batch, not a ticket queue.

Request a quote sales@rssechem.com

How to read a certificate of analysis Field by field: identity, purity, content basis, the retest date, and the questions worth asking a supplier before you file the document.How to choose a reference standard supplier A practical checklist for evaluating reference standard suppliers on documentation, traceability, lot consistency, logistics and technical support.Stable isotope-labelled standards and when to use them When labelled internal standards earn their place in an LC-MS or GC-MS method, what to specify when ordering, and the traps in quantitative work.Nitrosamine and NDSRI standards: what to test for and what to buy The difference between small nitrosamines and NDSRIs, what a laboratory needs as a standard for each, and how to specify one so the result stands up to review.What is an impurity reference standard? What the term means, how it differs from a pharmacopoeial standard and a working standard, what the documentation has to state, and how to pick the right form and purity basis.ICH M7 in practice: classifying mutagenic impurities How the five-class hazard assessment works, what the 1.5 microgram default really covers, and how the four control options decide which standards you buy.qNMR vs mass balance: how purity is really assigned Two certificates, one compound, two purity values. What mass balance and qNMR each measure, why the figures differ, and how the basis changes the number.Elemental impurities: from a PDE to a limit you can measure How a permitted daily exposure becomes a concentration limit, why the dose moves the number, and what an elemental impurity specification must state.Salt, hydrate and free base: converting content so the numbers reconcile How to move content and impurity values between as-is, anhydrous and free-base bases, in what order, and why the basis can turn a pass into a fail.Forced degradation study design: how far to push each stressor How to set stressor strength, read a kinetics screen, judge mass balance and catch over-degradation before it wastes a method development cycle.Analytical method transfer: acceptance criteria you can defend Four transfer routes, criteria built from the method's own precision, and the standard's assigned content that shifts every result by a fixed amount.Chiral and stereoisomeric impurity standards Enantiomer, diastereomer, epimer, E/Z isomer: four different standards and four different questions. What each has to state before it can control a method.Reference standard, analytical standard, CRM: what the words mean Four labels appear on the same vial in different catalogues. They are not synonyms, and the difference decides what you may claim in a report.Peptide reference standards: what changes when the analyte is a chain Deletion sequences, epimers, pyroglutamate, deamidation, counter-ion and water: why a peptide standard needs a different certificate from a small molecule.Cleaning validation residue limits: where the number comes from How a residue limit is derived from the dose, from 10 ppm and from a health-based PDE, and what the swab method and its standard must be able to reach.Cold chain and stability of reference standards: what transport and receipt checks protect Storage regimes, stability budgets and mean kinetic temperature, plus the receipt checks that decide whether a standard still supports its certificate.Impurity profile comparison: what a reference standard proves, and what it does not How reporting, identification and qualification thresholds set the scope of an impurity profile comparison, and where a standard stops proving anything.Weighing a reference standard: minimum weight and moisture How the 0.10% repeatability rule sets a minimum weight, why a hygroscopic standard is used as is, and which figures belong on the worksheet.Standard solution stability: how long a prepared standard can be used How to set a hold time for a standard solution: two baselines, six failure modes, a defensible study design and criteria fixed before the data arrive.